12/7/2020 Users Manual For Oreck Xl 2300 Series
6
Advertising
Oreck Xl Purifier Manual
Appliance manuals and free pdf instructions. Find the user manual you need for your home appliance products and more at ManualsOnline. Optimize your air purifier's performance with certified Oreck filter replacements. Oreck replacement filters are designed to keep your Oreck air purifier at peak performance. Need a little extra air help? Don't forget to try Oreck's air cleaning accessories including odor absorbing filters and scent cartridges.
6
9
5
IMPORTAN
![]()
T: Dry the Collector Cell thoroughly outside of Nikon d3000 user manual pdf download.
the Air Purifier before reinstalling it into the Air Purifier.
Ensure that all areas including corners and areas that may trap water are dry before reinstalling into the Air Purifier.
If the power indicator light is red after replacing Collector
Cell, then the Collector Cell is still wet. Remove Collector Cell and allow it to finish drying
Replacing The Charcoal Odor Absorber
(Optional)
In addition to air purification, your Oreck Air Purifier provides the
additional benefit of odor removal. The odor removal function is optional. Your Oreck Air Purifier will continue to remove harmful airborne particles with its permanent Electronic Collector Cell even if you choose not to use the optional Charcoal Odor Absorber.
Odor absorption effectiveness will gradually deteriorate over
time unless the Charcoal Odor Absorber is replaced. While every environment is different, Oreck suggests that the Charcoal Odor Absorber be replaced every two months or as needed. IMPORTANT: DO NOT wash the Charcoal Odor Absorber. Replace, if necessary.
Replacing Collector Cell After Cleaning
1. Snap in the Charcoal Odor Absorber (fig. 5).
2. Slide in the Pre-Filter (fig. 6).
3. Slide Collector Cell into cabinet, using handles (fig. 4).
4. Replace front grill. Unit is now ready for operation (fig. 3).
NOTE: An occasional “arcing” sound is normal when
operating the unit immediately after cleaning the Cell and should stop after a few minutes of operation.
Replacing Fragrance Cartridge
1. Open Fragrance Cartridge compartment by sliding the
Fragrance compartment release switch
(fig. 7).
2. Remove Fragrance Cartridge from center of the compartment
and replace with a new one
(fig. 8).
3. Close compartment until it locks (fig. 9).
NOTE:
One Fragrance Cartridge is included.
7
8
Advertising
Popular Brands
Popular manuals
Advertising
1
2
3
9
11
7
![]()
Unplug the air purifier.
Remove the top cover by sliding forward and lifting off.
Pull the Truman Cell
™
straight up and out of the cabinet by using the two small handles on each side
of the Truman Cell
™
.
Based on the frequency of arcing or how dirty the cell has become, perform one or both of the following steps:
If the cell is arcing frequently a “quick clean” can be performed by gently wiping a dry cotton swab
along the length of each of the four wires near the front of the cell to remove any built-up particles from the wires. Go to Step 9.
For a more complete cleaning, place the Truman Cell
™
in a sink, bathtub, dishwasher or other loca-
tion where cleaner and contaminants will rinse away without damaging surfaces and proceed to
Step 7. Note: If placed in dishwasher, do not insert dishwasher tongs directly into the collector cell as this may cuase damage to the wires or cell plates.
Spray Oreck Assail-a-Cell
®
cleaner thoroughly between each cell plate and cover each
surface. Allow the cleaner to soak for a few minutes and rinse with clean water. Do not let the
cleaner dry on the Truman Cell
™
.
An alternative method to clean the Truman Cell
™
is to soak it in warm water for two to three hours.
Mild liquid dish detergent may be used to help break down dirt. Rinse thoroughly with clean water.
Note: Do not insert objects to clean the Truman Cell
™
.
Tough residue such as tar from tobacco smoke may need additional applications or longer soaking.
Allow to dry completely outside of the air purifier. Do not use heated or compressed air to dry.
IMPORTANT: Do not reinsert the Truman Cell
™
until it is completely dry. If the “Check Collector
Cell” light blinks red after replacing the Truman Cell
™
, then the Truman Cell
™
may still be wet.
Remove the Truman Cell
™
and allow it to finish drying.
Place the Truman Cell
™
back into the unit by sliding it straight down into the slots. The Truman Cell
™
is specially designed so that it can be inserted only in one direction.
Replace the top cover, sliding back to lock into place. Be sure the top cover and front grill are
securely closed or the unit will not operate.
Reset the “Check Collector Cell” timer by holding down the Air Revitalizer button until the “Check
Collector Cell” light blinks three times.
1
2
3
4
5
7
8
9
10
11
Cleaning the Truman Cell
™
Note: The Truman Cell
™
may require more frequent cleaning if “arcing” occurs. Arcing is a sharp
snapping sound that occurs when large particles of dust are collected in the Truman Cell
. If prolonged
or continuous arcing occurs the Truman Cell
Oreck Xl Manual Download
™
should be cleaned.
IMPORTANT: Do not try to clean the Truman Cell
™
by inserting a cloth, brush, or other object between
the cell plates.
5
Oreck Xl Classic Manual
E
N
Oreck Xl Manual Pdf
G
L
I
S
Oreck Vacuum Xl Repair Manual
H
Oreck Xl Parts Manual
Advertising
Popular Brands
Popular manuals
Comments are closed.
|
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |